> >. Model EJXA. Differential Pressure Transmitter. Yokogawa Electric Corporation. Nakacho, Musashino-shi, Tokyo, EJXA Differential Pressure Transmitter – Yokogawa Supplier product_fld- ejxa. The high performance differential pressure transmitter EJXA features. User guide • Read online or download PDF • Yokogawa EJXA User Manual • Yokogawa Sensors.

Author: Vujar Bale
Country: Somalia
Language: English (Spanish)
Genre: History
Published (Last): 27 December 2010
Pages: 211
PDF File Size: 4.49 Mb
ePub File Size: 3.7 Mb
ISBN: 905-1-76154-303-6
Downloads: 54002
Price: Free* [*Free Regsitration Required]
Uploader: Babar

Diaphragm sealed differential pressure transmitters 76 pages. Outputs AO upper limit or AO lower limit. Yokogawa’s pressure transmitters as a patented real-time reverse check of the signal to ensure all calculations are preformed correctly. Power Supply Voltage and Load Resistance Installation of an Explosion-Protected Instrument Installation of an Explosion- the following precautions when selecting the installation Protected Instrument location.

But, Yokogawa goes a step further and adds a mechanical system within the capsule to protect the transmitter from over pressure events. To pipe by fastening a U-bolt to its mounting bracket.

EJX110A Differential Pressure Transmitter

Competitor’s analog sensors are passive. They do not supply a continual signal, so is the sensor still working when there is no signal? Absolute pressure and gauge pressure transmitters 76 pages. Page 27 Note 2. If this cannot be avoided, there must be CAUTION adequate ventilation as well as measures to prevent the leaking of rain water and the presence of standing water in the conduits. Yokogawa’s transmitters can withstand large overpressure events.

  JOAQUIN PORRERO PDF

Select the type of valve most appropriate for the application.

YOKOGAWA EJXA INSTALLATION MANUAL Pdf Download.

Yokogawa’s pressure transmitters use the industry standard IEC process connection deminsions. When your transmitter is ‘alarming’, you do not have the time to look for the manuals and go through them trying to figure out what is wrong; you need to get the transmitter up and operating again as quick as possible. Before mounting the transmitter to the process flange, affix the teflon film as follows: Yokogawa’s pressure transmitters have a long-term stability under all operational conditions.

Plants run better with Yokogawa differential pressure transmitters.

Yokogawa manufactures a communicator yojogawa your needs. Type 4X Note 2. They do not supply a continual signal, so, is the sensor still working when there is no signal?

By pressing ‘print’ button you will print only current page. Mounting the Flushing Connection Ring Impulse Piping Installation Precautions Check the capsule temp.

Add to my manuals Add. This manual also for: A failure to abide by these restrictions could The not be used in a hazardous area.

Yokogawa’s transmitter has 40 self-diagnostic checks to ensure that everything is running smoothly within the transmitter. Signal characterization is a versatile function available on all Yokogawa pressure transmitters.

Yokogawa pressure transmitters have construction features that are designed to allow it to outlive your plant. Maximum Internal Capacitance Ci: Add HART 7 manual. If the capillary tube is too long, loosely coil the 3. Changing the Direction of Integral Indicator First, the transmitter ykogawa a patented Back-check Technology that reverse checks all calculations in real-time.

  FOUNDATION OF INFORMATION TECHNOLOGY SUMITA ARORA CLASS X PDF

YOKOGAWA EJX110A Installation Manual

To some degree, all pressure sensors on the market provide stable measurement with variations in temperature and static pressure. Predictive impulse line blocking and stream tracing diagnostics lets you see problems before they happen.

All Yokogawa pressure transmitters are designed and certified to IEC Diaphragm Seals Installation Consideration When measuring flow, impulse lines must be the characteristics of the process fluid corrosiveness, routed together so that there ejx10a no temperature difference toxicity, flammability, etc.

The indicator can display any of the variables measured DP, SP, Capsule temperature ; alarm codes with short text; and a sweeping bar graph to give a graphical representation of the process. This system ensures that the transmitter is converting the signal from the sensor into the analog signal and digital protocol correctly.

Capsule temperature sensor problem. Absolute pressure and gauge pressure transmitters, ej series 65 pages.